ºÚÁÏÍø

ISSN: 2161-069X

Journal of Gastrointestinal & Digestive System
ºÚÁÏÍø

Our Group organises 3000+ Global Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ ºÚÁÏÍø Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

ºÚÁÏÍø Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)
  • Research Article   
  • J Gastrointest Dig Syst 2018, Vol 8(6): 582
  • DOI: 10.4172/2472-1220.1000582

Evaluation of the Portable THD® Anopress Device in Patients with Faecal Incontinence

Cosimo Alex Leo1,2, Jamie Murphy2*, Emanuel Cavazzoni3, Gregory P Thomas1, Shafaque Shaikh1, Jonathan D Hodgkinson1,2, Janindra Warusavitarne1,2 and Carolynne J Vaizey1,2
1St Mark’s Hospital and Academic Institute, London North West University NHS Trust, UK
2Imperial College London, UK
3Santa Maria della Misericordia Hospital, Perugia, Italy
*Corresponding Author : Jamie Murphy PhD, FRCS, St Mary’s Hospital, London, UK, Tel: 0044 020 3312 6666, Email: jamie.murphy@doctors.org.uk

Received Date: Nov 15, 2018 / Accepted Date: Nov 25, 2018 / Published Date: Dec 05, 2018

Abstract

Background: THD Anopress® has been promoted as a new portable anal manometer providing measurements of whole anal canal pressures. This study aims to report the anorectal function of patients suffering from Faecal Incontinence (FI) using this new device and the associated patient comfort.
Methods: We reviewed data from patients suffering from FI who had been evaluated with the Anopress. The St Mark’s score had been routinely used to evaluate the severity of FI. Manometric parameters and pressures were evaluated. Acceptability of this test was also assessed using the Visual Analogue Scale (VAS).
Results: THD Anopress® device was used to assess 60 patients with FI. The median baseline St Mark’s FI score was 14 (7-24). A mixed FI was seen in 34 (57%) patients. Resting pressures were 25 (0-60) in the female group and 30 (0-52) mmHg in the male group. Maximum squeeze increments were 27 (6-106) in the female and 42 (6-99) mmHg in male subject group. Maximum endurance squeeze in 10 seconds were 32 (5-89) in the female and 31 (10-65) mmHg in the male groups. Involuntary maximum squeeze was 33 (6-103) in the female group and 27 (7-90) mmHg in the male group. These values were significantly reduced when compared to previously report normative values. The median VAS is of 0 at insertion and during the procedure.
Conclusion: The THD Anopress® device appears to detect anal sphincter dysfunction in those with symptomatic FI and is well tolerated.

Keywords: Anorectal function; Anorectal manometry; Faecal incontinence; Anorectal physiology studies; THD Anopress®

Citation: Leo CA, Murphy J, Cavazzoni E, Thomas GP, Shaikh S, et al (2018) Evaluation of the Portable Anopress Device in Patients with Faecal Incontinence. J Gastrointest Dig Syst 8: 582. Doi: 10.4172/2472-1220.1000582

Copyright: © 2018 Murphy J, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

International Conferences 2024-25
 
Meet Inspiring Speakers and Experts at our 3000+ Global

Conferences by Country

Medical & Clinical Conferences

Conferences By Subject

Top