Altered Coiling with Stent Assistance for an Iatrogenic Traumatic Aneurysm of the Internal Carotid Artery

Akira Kurata1*, Sachio Suzuki1, Madoka Inukai1, Makoto Sasaki1, Kazuhisa Iwamoto1, Kuniaki Nakahara1, Shingo Konno2, Takao Kitahara2, Kiyotaka Fujii1 and Shinichi Kan3
1Departments of Neurosurgery, Kitasato University School of Medicine, Kanagawa, Japan
2Critical Care Medicine, Kitasato University School of Medicine, Kanagawa, Japan
3Radiology, Kitasato University School of Medicine, Kanagawa, Japan
Corresponding Author : Akira Kurata
Department of Neurosurgery
Kitasato University School of Medicine
1-15-1 Kitasato, Minamik Sagamihara
Kanagawa 228-8555, Japan
E-mail: akirak@med.kitasato-u.ac.jp
Received February 02, 2011; Accepted February 17, 2012; Published February 20, 2012
Citation: Kurata A, Suzuki S, Inukai M, Sasaki M, Iwamoto K, et al. (2012) Altered Coiling with Stent Assistance for an Iatrogenic Traumatic Aneurysm of the Internal Carotid Artery. OMICS J Radiology. 1:102. doi: 10.4172/2167-7964.1000102
Copyright: © 2012 Kurata A et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

Abstract

We report a rare case of a traumatic aneurysm which developed after clipping surgery with review of the relevant literature. Endovascular treatment using coiling and stent assistance taking into account technical considerations is described. Monitoring of the aneurysmal pressure showed marked decrease immediately after the stent emplacement.

Citations : 551

Indexed In
  • Index Copernicus
  • Google Scholar
  • Open J Gate
  • Genamics JournalSeek
  • ResearchBible
  • Electronic Journals Library
  • RefSeek
  • Hamdard University
  • EBSCO A-Z
  • OCLC- WorldCat
  • SWB online catalog
  • Virtual Library of Biology (vifabio)
  • Publons
  • Geneva Foundation for Medical Education and Research
  • ICMJE
Share This Page
International Conferences 2025-26
 
Meet Inspiring Speakers and Experts at our 3000+ Global

Conferences by Country

Medical & Clinical Conferences

Conferences By Subject

Top