Comparison of Hallux Valgus Deformity Evaluation on Printed Versus Digital X-Rays

Ehud Atoun*, Ezequiel Palmanovich, Zeev Feldbrin, Ronen Debi, Guy Fridman and Meir Nyska
University Children's Hospital Basel, Spitalstrasse 33, CH-4056, Israel
Corresponding Author : Ehud Atoun
University Children's Hospital Basel
Spitalstrasse 33, CH-4056, Israel
Tel: 00972537678722
E-mail: dratoun@gmail.com
Received: September 21, 2015 Accepted: December 21, 2015 Published: December 29, 2015
Citation: Atoun E, Palmanovich E, Feldbrin Z, Debi R, Fridman G, et al. (2015) Comparison of Hallux Valgus Deformity Evaluation on Printed Versus Digital X-Rays . Clin Res Foot Ankle 3:177. doi:10.4172/2329-910X.1000177
Copyright: © 2015 Atoun E, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
Related article at ,

Abstract

Background: Evaluation of hallux valgus deformity was traditionally made on a printed X-ray image. In the last two decades, digital X-ray systems have begun to replace the analog images, and images are not routinely printed anymore. Clinicians have to evaluate X-rays on digital images viewed on the computer monitors. This study compares the intra- and inter-observer reliability of foot deformity evaluation on printed images with measurements on computer monitors with the guidance of dedicated software.
Methods: Fifteen pre-operative X-rays reports of patients who were candidates for a surgical correction of hallux valgus deformity, were evaluated by ten orthopedic surgeons. Each surgeon had two evaluation sessions on each modality, printed and computer monitor with the guidance of dedicated software.
Results: We found that the hallux valgus deformity evaluations on computer monitors had significantly lower inter- and intra-observer variations than the evaluations performed on printed images. This study validates the use of digital X-ray measurements on computer monitors with the guidance of dedicated software. for evaluation of hallux valgus deformity.
Conclusion: Clinician can use digital images with the guidance of dedicated software to evaluate for deformities without a need to print the images.