  • Research Article   
  • J Clin Exp Pathol 2018, Vol 8(2): 344
  • DOI: 10.4172/2161-0681.1000344

Xylene/Chloroform Free Microwave Tissue Processing and Staining a Non-hazardous and Time Effective Alternative

Swaroop Raj1*, Divya C2 and Harendra Kumar1
1Department of Pathology, Sri Devaraj Urs Medical College, Kolar, Karnataka, , India
2Department of Anatomy, Sri Devaraj Urs Medical College, Kolar, Karnataka, , India
*Corresponding Author : Swaroop Raj, Assistant Professor, Department of Pathology, Sri Devaraj Urs Medical College, Kolar, Karnataka, India, Tel: +919844044473, Email: dr.swaroop.raj@gmail.com

Received Date: Mar 06, 2018 / Accepted Date: May 14, 2018 / Published Date: May 21, 2018

Abstract

Introduction: Tissue processing using xylene/chloroform has been employed in histopathology reporting for the past 100 years. technique has not only reduced the processing time from 1 day to one hour but also doesn’t use xylene/chloroform and has been found to be on par with conventional processing. Xylene is expensive and detrimental to human health. The present study replaces chloroform with isopropanolol in tissue processing and xylene with liquid dish wash solution (LDW) in staining which is not only cheap but also non bio hazardous.
Aim:
To assess the efficacy of xylene free processing (microwave) and staining versus conventional tissueprocessing and hematoxylin and eosin are staining.
Materials and methods:
Two Tissue bits from 15 consecutively submitted samples at RL Jalappa Hospital after 1st Jan 2015 each of breast, cervix, lymph node, fat, thyroid, skin, alimentary tract, muscle, salivary gland, liver and kidney were taken and one was processed and stained using conventional method, other using xylene/chloroform free processing and conventional staining and other with both xylene/chloroform free processing and staining. The 495 sections were evaluated and scored by two pathologists independently for nuclear staining, cytoplasmic staining, uniformity, clarity and crispness.
Results:
In the samples evaluated xylene free processing and staining seems to be on par with conventional xylene processed and stained sections terms of nuclear and cytoplasmic detail, clarity and crispness. However Xylene cleared sections showed slightly better uniform staining (p value->0.05)
Conclusion:
Xylene/chloroform free processing and staining is not only a rapid but also safe alternative to conventional processing and staining using xylene. However more extensive studies need to be done on other types of tissues for validation

Keywords: Xylene; Alternative; Microwave processing; Liquid dish wash; Xylene free staining

Citation: Swaroop R, Divya C, Harendra K (2018) Xylene/Chloroform Free Microwave Tissue Processing and Staining a Non-hazardous and Time Effective Alternative. J Clin Exp Pathol 8:344. Doi: 10.4172/2161-0681.1000344

Copyright: © 2018 Raj S, et al. This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.

International Conferences 2024-25
 
Meet Inspiring Speakers and Experts at our 3000+ Global

Conferences by Country

Medical & Clinical Conferences

Conferences By Subject

Top