ºÚÁÏÍø

ISSN: 2155-9872

Journal of Analytical & Bioanalytical Techniques
ºÚÁÏÍø

Our Group organises 3000+ Global Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ ºÚÁÏÍø Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

ºÚÁÏÍø Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)
Citations : 4454

Indexed In
  • CAS Source Index (CASSI)
  • Index Copernicus
  • Google Scholar
  • Sherpa Romeo
  • Academic Journals Database
  • Open J Gate
  • Genamics JournalSeek
  • JournalTOCs
  • ResearchBible
  • China National Knowledge Infrastructure (CNKI)
  • Ulrich's Periodicals Directory
  • Electronic Journals Library
  • RefSeek
  • Directory of Research Journal Indexing (DRJI)
  • Hamdard University
  • EBSCO A-Z
  • OCLC- WorldCat
  • Scholarsteer
  • SWB online catalog
  • Virtual Library of Biology (vifabio)
  • Publons
  • Euro Pub
  • ICMJE
Share This Page

Development of new stigmatic imaging mass spectrometer and its application to metal cation distribution in fish

6th International Conference and Exhibition on Analytical & Bioanalytical Techniques

Jun Aoki

Osaka University, Japan

ScientificTracks Abstracts-Workshop: J Anal Bioanal Tech

DOI:

Abstract
Measurement methods of spatial distribution of molecules such as proteins and drugs at cellular-scale are required in many fields. Recently, scanning type imaging mass spectrometry (IMS) with matrix-assisted laser desorption/ionization (MALDI) is intensively used for biomolecular analysis. However, the spatial resolution of scanning MALDI-IMS is limited by to about 10 - 100 �¼m and inadequate for cellular-scale observation. Therefore, we are developing a stigmatic MALDI imaging mass spectrometer for higher spatial resolution. The experimental apparatus consists of a MALDI ion source, a multi-turn time-of-flight mass spectrometer (MULTUM) and a time and position sensitive delay line detector. Ion distributions at the sample plate are magnified and projected with the ion optical lens system onto the detector. The ion optical system of MULTUM satisfies the perfect spatial and temporal focusing condition, so that the spatial distributions of ions conserved after circulation. Our evaluation experiment demonstrated that both the spatial resolution of 1 micro-meter and the mass resolving power of 10000 were simultaneously achieved. We applied this new apparatus to several practical applications, for example observation of the distribution of accumulated metal cations in fish. We used medaka (Oryzias latipes) as samples for observing the bioaccumulation of Sr and Cs. Medaka were raised for two weeks in water containing 0.001 mol/L SrCl2 and 0.05 mol/L CsI. Distributions of Cs and Sr in a sliced section of medaka are obtained with a micrometer-scale spatial resolution.
Biography

Jun Aoki has completed his PhD from Kyoto University. He is the Assistant Professor of Osaka University. His field of expertise is imaging mass spectrometry. He prized the Mass Spectrometry of Japan Research Award in 2012.

Email: ajunmail@mass.phys.sci.osaka-u.ac.jp

International Conferences 2024-25
 
Meet Inspiring Speakers and Experts at our 3000+ Global

Conferences by Country

Medical & Clinical Conferences

Conferences By Subject

Top