黑料网

ISSN:2167-7964

Journal of Radiology
黑料网

Our Group organises 3000+ Global Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ 黑料网 Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

黑料网 Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)
Citations : 551

Indexed In
  • Index Copernicus
  • Google Scholar
  • Open J Gate
  • Genamics JournalSeek
  • ResearchBible
  • Electronic Journals Library
  • RefSeek
  • Hamdard University
  • EBSCO A-Z
  • OCLC- WorldCat
  • SWB online catalog
  • Virtual Library of Biology (vifabio)
  • Publons
  • Geneva Foundation for Medical Education and Research
  • ICMJE
Share This Page

Comparison of effective dose using constant conversion, SSDE and patient specific MC simulations in chest CT

3rd International Conference on Radiology and Imaging

Yogesh Thakur

The University of British Columbia, Canada

ScientificTracks Abstracts: OMICS J Radiol

DOI:

Abstract
CT examinations are identified as the largest radiation dose/exam contributor to the population from medical imaging. The AAPM report 204 advocated the use of Size Specific Dose Estimates (SSDEs) to dose estimation; however effective dose calculation using SSDE has not been validated. This work aims to determine whether the published k-factor for chest CT is valid using SSDE approach. 24 patients underwent clinically indicated chest CT exams, scanned with our institutional CT protocol. Patient data was categorized into 4 groups based on sex and BMI (large: >25 kg/m2 and small: <25 kg/m2). Monte Carlo (MC) simulations were performed using patient data to estimate organ absorbed dose and calculate E via ICRP-103 methods (E-MC) and compared with E estimated with k-factor (E-k) and with SSDE/k-factor (E-SSDE). A significant difference was found between E-MC and E-k for small females (P<0.05). Differences in E-SSDE and MC-E were significantly different for all groups (P<0.05) except small females, where the difference between E-SSDE and E-MC was not significantly different (P>0.05). The range of difference between E-MC and E-k was +/- 0.8 mSv. Dose was underestimated by 45% for the smallest female (BMI-17.0). Data suggested that E-k is valid to estimate effective dose in chest CT for males between 17-32 BMI and females between 26-30 BMI. Small females were significantly underestimated using the E-k method by upto 45%. SSDE improved E estimates for small females. Use of the currently established k-factor of 0.014 mSv/(mGy-cm) is a valid method to estimate effective dose for males and large females in chest CT.
Biography

Yogesh Thakur completed his PhD at The University of Western Ontario in 2009. He is currently the Medical Physics Lead at Vancouver Coastal Health Authority and a Clinical Assistant Professor in the Department of Radiology at the University of British Columbia. He has published more than 15 papers in reputed journals, 1 book chapter, and peer reviewed manuscripts for numerous reputed journals. He is a member of the Canadian College of Physicists in Medicine, certified in Diagnostic Imaging and Mammography.