ºÚÁÏÍø

ISSN:2167-7964

Journal of Radiology
ºÚÁÏÍø

Our Group organises 3000+ Global Events every year across USA, Europe & Asia with support from 1000 more scientific Societies and Publishes 700+ ºÚÁÏÍø Journals which contains over 50000 eminent personalities, reputed scientists as editorial board members.

ºÚÁÏÍø Journals gaining more Readers and Citations
700 Journals and 15,000,000 Readers Each Journal is getting 25,000+ Readers

This Readership is 10 times more when compared to other Subscription Journals (Source: Google Analytics)
Citations : 551

Indexed In
  • Index Copernicus
  • Google Scholar
  • Open J Gate
  • Genamics JournalSeek
  • ResearchBible
  • Electronic Journals Library
  • RefSeek
  • Hamdard University
  • EBSCO A-Z
  • OCLC- WorldCat
  • SWB online catalog
  • Virtual Library of Biology (vifabio)
  • Publons
  • Geneva Foundation for Medical Education and Research
  • ICMJE
Share This Page

Reconstruction quality in 4D cone-beam computed tomography incorporated with deformable image registration method

2nd World Congress on Medical Imaging and Clinical Research

Dongyeon Lee, Hyosung Cho and Uikyu Je

Yonsei University, South Korea

Posters & Accepted Abstracts: OMICS J Radiol

DOI:

Abstract
In conventional three-dimentional (3D) cone-beam computed tomography (CBCT) reconstruction, the image quality of reconstructed images is typically degraded due to patient�s motion such as respiration and heartbeat. In order to solve these difficulties, 4D CBCT incoporated with a phase-angle sorting scheme is often utilized. However, in this case, it requires dense projections in each phase to obtain reconstructed images of high quality and also severe aliasing artifacts are often present due to the limited number of projections at each phase used in the reconstruction. In this study, as an alternative, we propose an effective method for reducing motion blur and aliasing artifacts in conventional 4D CBCT reconstruction, the so-called deformable image registration (DIR), and made a quantitative comparison of the reconstruction qualities by both shcemes. In the proposed method, DIR process is carried out in two different ways as follows. In the first way, DIR process is applied to the resultant reconstructed images in 4D CBCT, while in the second way to the original projections on the basis of the reconstructed projections that are produced by forwardprojecting the reconstructed CBCT images in a single phase. The latter process is possibly performed using the adaptive steepestdescent POCS (ASD-POCS) algorithm for high reconstruction quality. Our results indicate that the motion blur and aliasing artifacts in the reconstructed CBCT images by using the DIR method were more significantly reduced, compared to the phase-angle sorting method. In addition, the second method in the DIR process seems more effective for reducing imaging dose than the first method.
Biography

Dongyeon Lee completed his MS degree from Yonsei University, Republic of Korea, and is a PhD candidate in the Department of Radiation Convergence Engineering at Yonsei University. He has published more than 10 papers in reputed journals and his research interests include CT, image registration, GPU acceleration, and so on.